Heco Answer Center

615 HVAC Questions, Answered Clearly

Search Heco's growing HVAC knowledge library for repair symptoms, maintenance, parts, heat pumps, replacement planning, permits, rebates, commercial systems and more.

Heco HVAC · Experience since 2006 · California contractor license #1050351

Heco Heating and Air Conditioning

11 matching answers

Clear filters

The furnace may begin a normal startup sequence but never light the burners, or the ignitor may be visibly damaged. Ignition failures can also come from controls, gas supply or safety circuits, so confirmation is needed.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Yes. An ignitor can sometimes glow without reaching the required condition for reliable ignition, and voltage/control issues can mimic an ignitor fault. The ignition sequence should be diagnosed as a system.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

No. It is a combustion-safety control. The underlying draft/venting condition must be diagnosed rather than bypassing the switch for operation.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Do not repeatedly reset a rollout switch. It may indicate blocked venting, burner problems or heat-exchanger/combustion issues that need diagnosis before the furnace is operated again.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Restricted airflow, blower problems, dirty components or abnormal heat input can overheat the furnace. The cause should be corrected rather than replacing the limit switch as a first step.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

The control may be attempting ignition while a gas-valve, ignitor, flame-proving, pressure-switch or other safety condition prevents successful burner operation. Gas/combustion diagnosis should be left to a technician.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

It sequences blower, inducer, ignition, gas-valve and safety inputs in many modern furnaces. A board should be condemned only after its power, inputs, wiring and controlled components are verified.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Yes. A bad sensor, motor, transformer, thermostat signal or wiring issue can make the board appear faulty. Confirm inputs and outputs before replacing an expensive board.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

It provides a diagnostic clue from the control board, such as an ignition, pressure-switch, limit or flame-proving fault. The code narrows the investigation but does not by itself prove which part failed.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Yellow or unstable flame can indicate combustion, air, burner or venting problems. Because poor combustion can create carbon monoxide, shut down abnormal equipment and have it inspected.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research

Possible causes include the pilot assembly, thermocouple/flame-proving component, drafts or gas/venting issues. Because this involves gas combustion, persistent pilot failure should be professionally serviced.

Reviewed by Heco HVAC Reference basis: HVAC parts/troubleshooting research
Trusted references

Official information behind our guidance

Equipment condition still requires professional evaluation. For regulations, rebates and efficiency guidance, Heco checks authoritative sources and identifies items that can change.

Your equipment needs a specific answer.

Tell Heco the symptom, equipment type, property type and location. We will help identify the next practical step.