EPA recommends MERV 13 or the highest rating a system can accommodate. A technician can help verify whether the blower and filter arrangement can handle the pressure drop.
615 HVAC Questions, Answered Clearly
Search Heco's growing HVAC knowledge library for repair symptoms, maintenance, parts, heat pumps, replacement planning, permits, rebates, commercial systems and more.
Heco HVAC · Experience since 2006 · California contractor license #1050351
No heat? Start with your symptom.
Detailed homeowner guides explain safe checks, possible causes and when to request professional diagnosis.
What do you need help understanding?
Start with a symptom
Search what you observe—not what you think the failed part is. Several HVAC faults can produce the same symptom, and an on-site diagnosis is often needed before choosing a repair.
615 matching answers · page 6 of 21
HEPA is a high-efficiency particle filtration standard commonly used in portable air cleaners and specialized systems. A standard residential HVAC filter slot may not be designed for true HEPA resistance.
No. EPA emphasizes source control and ventilation first, with filtration as a supplement. No single air cleaner removes every type of pollutant.
Properly sized portable air cleaners with high particle-removal performance and suitable HVAC filtration can reduce indoor fine particles. Outdoor smoke conditions, building leakage and filter capacity all affect results.
Particle filtration may reduce airborne allergens and can improve some symptoms for some people, but it is not a medical treatment and should be combined with source control and cleaning.
HVAC filters and air cleaners can reduce some airborne particles, including particles that may contain viruses, but filtration alone does not eliminate infection risk.
EPA advises against using ozone generators in occupied spaces because ozone is a lung irritant and is not an effective general solution for indoor pollution at safe concentrations.
Clean Air Delivery Rate indicates how much filtered air a portable air cleaner delivers for certain particles. Room size and ceiling height should be considered when selecting a unit.
Longer fan operation can increase filtration because more air passes through the filter, but it also uses fan energy and can affect humidity in some cooling systems. The best strategy depends on equipment and IAQ goals.
HVAC filtration may reduce some particles, but odors can come from moisture, chemicals, drains, combustion or other sources. Identify and control the source rather than relying only on filtration.
Source control means reducing or removing the pollutant source itself—for example, controlling moisture, avoiding indoor smoking or properly venting combustion appliances. EPA considers it a primary IAQ strategy.
Room size is important, but also consider particle-removal performance, CADR, noise, filter availability and whether the device intentionally produces ozone. Follow EPA and manufacturer guidance.
EPA generally recommends keeping indoor relative humidity around 30% to 50% to reduce moisture problems while maintaining comfort.
Possible causes include oversized equipment, short cycling, high outdoor moisture, ventilation/infiltration, low airflow or system control issues. Humidity problems should be diagnosed with temperature and moisture measurements.
Yes. An oversized system may satisfy the thermostat quickly and shut off before removing enough moisture, especially in humid conditions.
Filters can capture some airborne particles, but they do not fix the moisture source that allows mold to grow. Moisture correction and cleanup are essential.
EPA recommends addressing the moisture cause first. Wet or moldy internal duct insulation generally cannot be effectively cleaned and may need replacement; visible contamination should be properly evaluated.
EPA does not recommend routine duct cleaning for every home. It may be considered when there is substantial visible mold, vermin infestation, or excessive debris being released from ducts.
Evidence that cleaning ducts alone improves system efficiency is limited. Cleaning certain HVAC components may help when they are dirty, but sealing leaks and correcting airflow often have clearer efficiency value.
Whole-house ventilation uses fans and ducts to provide controlled outdoor-air exchange. Common approaches include exhaust, supply, balanced and energy-recovery systems.
A tighter building reduces uncontrolled air leakage, which saves energy but can allow indoor pollutants to accumulate. Controlled ventilation helps manage fresh-air exchange.
An energy-recovery ventilator exchanges stale indoor air with outdoor air while transferring some heat and, depending on design, moisture between air streams to reduce ventilation energy penalty.
A heat-recovery ventilator exchanges indoor and outdoor air while transferring heat between the air streams. It provides ventilation with less heating/cooling energy loss than uncontrolled ventilation.
Condensation can occur when a cold surface falls below the dew point of surrounding humid air. Causes can include high indoor humidity, duct insulation problems, air leakage or very cold supply conditions.
Condensate drains carry moisture removed during cooling. Slime, debris, improper slope or drain design can cause repeated clogs; recurring problems should be corrected rather than only cleared repeatedly.
Yes. Inadequate outdoor-air exchange can allow pollutants and odors to accumulate. Source control, local exhaust and whole-house ventilation are common strategies.
Natural ventilation can help when outdoor conditions are suitable, but it is uncontrolled and may be impractical during heat, smoke or poor outdoor air quality. Mechanical ventilation provides more predictable airflow.
Refrigerant is the working fluid that absorbs and releases heat as it circulates through the refrigeration system. It should remain in a sealed circuit during normal operation.
No. Refrigerant circulates in a closed system; a low charge usually indicates a leak, incorrect initial charge or service issue rather than normal consumption.
R-22 is an older HCFC refrigerant formerly common in residential AC and heat pumps. New R-22 systems are no longer sold, but existing equipment may still be serviced using recovered/reclaimed or previously produced refrigerant.
Official information behind our guidance
Equipment condition still requires professional evaluation. For regulations, rebates and efficiency guidance, Heco checks authoritative sources and identifies items that can change.
Your equipment needs a specific answer.
Tell Heco the symptom, equipment type, property type and location. We will help identify the next practical step.